RO-CTOP High TDS

The causes to the High TDS are listed in the timeframe that you've owned your RO system. The grey background applies to systems in use for under 3 months and the white background applies to systems in use for more than 3 months

 
Causes
Identify
Solution
1
Feed water blocked

 

Make sure all lines to the RO system and within the RO head are not obstructed. Low water pressure result in slightly higher tds than good water pressure.

 

Untangles the lines and make sure all valves are fully turned on.
2

 

Wrong membrane direction

3

Forgot to insert membrane

TDS test

Normally without the membrane, the RO water's ppm is equivalent to the Tap water's ppm.

4
Defective Membrane

(Extremely Rare)

5
Clogged pre-filters

Flow rate test

Clogged pre-filters inadvently lowers the water pressure. Thus cause the tds to escalate.

6
Depleted Membrane

Reading next