APEC Light Reverse Osmosis Commercial Systems
- Ultra Pure & Safe Filtered Drinking Water
- Fresh, Crisp Taste Superior to Bottled Water
- 180, 240, 360 Gallons/day Commercial Output
- 14 Gallon Pressurized Tank Included
- Suitable for Restaurants, Offices, Large Homes, Schools
- Can treat wide range of Contaminated Water
- Systems built with Super Long Lasting US MADE Filters
- Constructed of High Quality Performance Parts
- Direct from Original Manufacturer With Lifetime Tech Support
- Lab Tested to Guarantee High Rejection Rate
More information
Flow Rate with Variable Pressure and Temperature:
When sizing a system, particularly if system output is critical for you, you need to understand that the actual flow rate GPD(Gallons Per Day) of any reverse osmosis system depends on the input water pressure, temperature, and water conditions. The higher your input water pressure and temperature, the higher the pure water output. The industry standard*, which is the same as our standard, is set at 60 psi pressure and 77° F(25° C) temperature.
Output at 77 °F VS. Various Input Water Pressure
ITEM #
RO-LITE-180
RO-LITE-240
RO-LITE-360
40 psi
120 GPD
160 GPD
175 GPD
50 psi
150 GPD
200 GPD
220 GPD
60 psi
180 GPD
240 GPD
270 GPD
70 psi
220 GPD
280 GPD
317 GPD
80 psi
250 GPD
320 GPD
360 GPD
*Please note that this standard is not necessarily followed by all vendors. We have seen other RO systems claiming 100 GPD at 100 psi —very unrealistic input water pressure! So do check on these facts before you make a buying decision.
More on water temperature: While the industry standard temperature is set at 77 °F, we know that not everyone has 77 °F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your RO system at different temperatures.
INSTRUCTIONS: find your water temperature and its factor, divide the RO system GPD by that factor, and you will get the temperature-corrected output.
ºC
ºF
Factor
3
37.4
3.03
5
41
2.58
7
44.6
2.22
9
48.2
2.00
11
51.8
1.78
13
55.4
1.61
15
59
1.47
17
62.6
1.34
19
66.2
1.24
21
69.8
1.15
23
73.4
1.08
25
77
1.00
27
80.6
0.94
29
84.2
0.88
31
87.8
0.83
33
91.4
0.77
35
95
0.73
37
98.4
0.69
Light Commercial RO Specifications:
System Capacity
RO-LITE-180: 180 gallons/day @ 60 psi When Systems At 77 DegreeF water temperature
RO-LITE-240: 240 gallons/day @ 60 psi When Systems At 77 DegreeF water temperature
RO-LITE-360: 360 gallons/day @80 psi When Systems At 77 DegreeF water temperature
Tank Capacity
14 Gallon
Feedwater Pressure
40 - 80 Psi
Feedwater Temperature
40-100°F
Feed Water pH
2.0 - 11.0
Max Total Dissolved Solid
2,000 ppm
System Dimensions
RO System: 15" L x 8" W x 29" H
Tank-14: 16" D x 16" W x 22" H
System Packaging Weight
RO System: 45 lbs
Tank-14: 25 lbs
Shipping & Returns
We are proud to offer 1 day order processing (excluding weekends and holidays). Orders that are placed prior to 12:00 pm PST with express shipping services will be guaranteed to ship out the same day – subject to order verification and credit approval. Our shipping charges are based on the method of service and the location.
Products can be returned within 30 days from the date of invoice. Please carefully review APEC's Return Policy details and conditions.
Flow Rate with Variable Pressure and Temperature:
When sizing a system, particularly if system output is critical for you, you need to understand that the actual flow rate GPD(Gallons Per Day) of any reverse osmosis system depends on the input water pressure, temperature, and water conditions. The higher your input water pressure and temperature, the higher the pure water output. The industry standard*, which is the same as our standard, is set at 60 psi pressure and 77° F(25° C) temperature.
Output at 77 °F VS. Various Input Water Pressure
ITEM #
RO-LITE-180
RO-LITE-240
RO-LITE-360
40 psi
120 GPD
160 GPD
175 GPD
50 psi
150 GPD
200 GPD
220 GPD
60 psi
180 GPD
240 GPD
270 GPD
70 psi
220 GPD
280 GPD
317 GPD
80 psi
250 GPD
320 GPD
360 GPD
*Please note that this standard is not necessarily followed by all vendors. We have seen other RO systems claiming 100 GPD at 100 psi —very unrealistic input water pressure! So do check on these facts before you make a buying decision.
More on water temperature: While the industry standard temperature is set at 77 °F, we know that not everyone has 77 °F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your RO system at different temperatures.
INSTRUCTIONS: find your water temperature and its factor, divide the RO system GPD by that factor, and you will get the temperature-corrected output.
ºC
ºF
Factor
3
37.4
3.03
5
41
2.58
7
44.6
2.22
9
48.2
2.00
11
51.8
1.78
13
55.4
1.61
15
59
1.47
17
62.6
1.34
19
66.2
1.24
21
69.8
1.15
23
73.4
1.08
25
77
1.00
27
80.6
0.94
29
84.2
0.88
31
87.8
0.83
33
91.4
0.77
35
95
0.73
37
98.4
0.69
Light Commercial RO Specifications:
System Capacity
RO-LITE-180: 180 gallons/day @ 60 psi When Systems At 77 DegreeF water temperature
RO-LITE-240: 240 gallons/day @ 60 psi When Systems At 77 DegreeF water temperature
RO-LITE-360: 360 gallons/day @80 psi When Systems At 77 DegreeF water temperature
Tank Capacity
14 Gallon
Feedwater Pressure
40 - 80 Psi
Feedwater Temperature
40-100°F
Feed Water pH
2.0 - 11.0
Max Total Dissolved Solid
2,000 ppm
System Dimensions
RO System: 15" L x 8" W x 29" H
Tank-14: 16" D x 16" W x 22" H
System Packaging Weight
RO System: 45 lbs
Tank-14: 25 lbs
We are proud to offer 1 day order processing (excluding weekends and holidays). Orders that are placed prior to 12:00 pm PST with express shipping services will be guaranteed to ship out the same day – subject to order verification and credit approval. Our shipping charges are based on the method of service and the location.
Products can be returned within 30 days from the date of invoice. Please carefully review APEC's Return Policy details and conditions.